On-site water testing, without the courier delays.

Water Lab 1.0 is a wireless, Bluetooth-enabled water testing kit that runs 11 different water tests with high accuracy from a single handheld system — giving you lab-grade data on-site, in minutes, instead of days.

You can't fix water chemistry
you haven't measured.

Water Lab 1.0 turns a multi-day lab courier round trip into an on-site reading, in minutes.

HOW IT WORKS

A triple-wavelength photometer that fits in one hand

Water Lab 1.0 uses a triple-wavelength (530/570/620nm) photometer with a changeable cuvette for direct-immersion sampling. Results sync over Bluetooth 4.0 to a companion app and free cloud server, which calculates dosage recommendations and the Langelier Saturation Index (LSI), and generates a printable report — all from a simple 6-button interface, rated IP68 for full waterproof durability.

  • Bluetooth sync to app + free cloud server for instant reporting
  • Automatic dosage recommendations and LSI calculation
  • IP68 waterproof housing built for site conditions
  • Changeable cuvette supports direct-immersion sampling
11 PARAMETERS, ONE DEVICE

Full water chemistry, without sending samples off-site

A single system tests pH, Free/Combined/Total Chlorine, Alkalinity, Cyanuric Acid, Active Oxygen (MPS), Bromine, Chlorine Dioxide, Ozone, Hydrogen Peroxide, and Total/Calcium Hardness — the baseline data used to size and validate ACCS™ and SBR™ installations, and to track treatment performance over time.

11
Test parameters
On-site
Sampling & results
Cloud
Data & report history
Request a free site assessment ›
FULL SPEC SHEET

Every parameter, its measurement range, and its reagent

For engineers who need the exact numbers before they trust the result — the full range and reagent used for each of the 11 parameters Water Lab 1.0 measures.

ParameterRangeReagent
pH value6.50 – 8.40 pHPhenol Red Photometer
Chlorine (Free / Combined / Total)0.00 – 6.00 mg/l (ppm)DPD N°1 Photometer / DPD N°3 Photometer
Alkalinity (Acid Capacity)0 – 300 mg/l (ppm) CaCO₃Alkalinity-M Photometer
Cyanuric Acid (Stabilizer)0 – 160 mg/l (ppm)CYA-Test Photometer
Active Oxygen (MPS)0.0 – 30.0 mg/l (ppm)*DPD N°4 Photometer*
Bromine0.0 – 13.5 mg/l (ppm)**DPD N°1 Photometer + Glycine*
Chlorine Dioxide0.0 – 11.4 mg/l (ppm)**DPD N°1 Photometer + Glycine*
Ozone0.00 – 4.00 mg/l (ppm)**DPD N°1 / DPD N°3 Photometer + Glycine*
Hydrogen Peroxide0.00 – 2.90 mg/l (ppm)*Hyd. Peroxide LR Photometer*
Total Hardness0 – 500 mg/l (ppm)*Acidifying PT Photometer* / POL20TH1* / POL10TH2*
Calcium Hardness0 – 500 mg/l (ppm)*POL20CaH1* / POL20CaH2*

* High-range reagent set. ** Requires glycine addition for interference-free reading. All ranges are photometer-measured, on-site, in minutes.

WHERE IT'S USED

Cooling towers, swimming pools, STP, and potable water

Water Lab 1.0 is used across cooling tower circuits, swimming pools, sewage treatment plant (STP) water, and potable water systems — anywhere a fast, accurate on-site read matters more than a lab courier turnaround.

Free facility audit

Know your water
before you treat it.

Ask our engineers about an on-site Water Lab 1.0 test.

Or email us at info@cet-enviro.com